Technical Data

Test Standard Classification
Inflammability DIN 4102 B1
Pendular hardness on glass DIN 53157 Minimum ca. 100 swings
Chemical Resistance DIN 68861 TL1 1B
Abrasivity S33 DIN 68861 TL2 IP > 1.500 cycles
Scratch Resistance DIN 68861 TL4 4B
Heat Test EN12722 120ºC- no marks
Cross Cut Test DIN 53151 GT 0 – no removal
Metal Scratches Steel wool test No marks
Scratch Resistance Hamberger Planner > 30 Newton

Environmental Certificate

  • Contain no dangerous (poisonous) substances according to the Declaration of Wood lacquer System (Verband der Lackindustrie e.v., VdL-RL 02);
  • Contain no cancer causing substances according to the yearly update of the estimation basis TRG 900 – TRGS 905 list;
  • No chlorinated or chlorofluorchydrocarbon (FCKW) products used in the production;
  • No Peru-Baisam or potassium dichromate used in the production;
  • No preservatives or additives based on PCB, Lindan or chemically related substances have been used;
  • Contain no pesticides and/or fungicides;
  • Contain no formaldehyde and none is released at any other period in time;
  • Contain no asbestos;
  • Non-readily ignitable according to DIN 4102, B1, with the application of base coats that correspond to DIN 4102 B1; and
  • The Quality Standard EN 71 is fulfilled.
General Building Supervision Test Report
Item Tested MIRAPHEN-UV-Sealer with MIRAPHEN-UV-Top Coat on hardly inflammable plywood - also veneer – as a hardly inflammable building material (building material category DIN 4102 – B1)
Result The above mentioned item is applicable according to the meaning of the State building regulations.